+1 (630) 645-0600 [email protected]

Flame COVID-19 Variants Amplification Kit test 100

qPCR Master Kit – CE-IVD

The kit is able to simultaneously detect the presence of COVID infection of both the “common” strain and the English, South African and Brazilian P2 and other Variant Of Concern with RT-PCR the method in a single “well”. Not Sequencing required!

Purchasing Information: https://chinchillalife.com/flame-covid-19-variants-amplification-kit-test-100/

The kit is able to simultaneously detect the presence of COVID infection of both the “common” strain and the English, South African and Brazilian P2 and other Variant Of Concern with RT-PCR the method in a single “well”. Not Sequencing required!

This kit is designed with specific primers and Taqman probes for the New Coronavirus ORF1ab and the conservative region of the N gene sequence encoding the nucleocapsid protein of the new coronavirus to diagnose or differentially diagnose whether the tested patient is infected with the new coronavirus, the strain-specific N501Y mutation site and the strain-specific E484K mutation sites.

It’s available now the Flame DELTA VARIANT Reflex Reagent Kit for specific detection of all DELTA Variats. The Flame DELTA VARIANT Reflex Reagent Kit contains specific probes and positive controls and it’s just to be added to Flame CoViD-19 Variants qPCR Master kit in second level test in case of sample SARS-CoV-2 positive but N501Y-E484K negative.

The mix contains:

2 specific genes: Orf 1ab and N

Genomic Internal control

Specific sequences for the N501Y Mutation

Specific sequences for the E484K Mutation

4 channels required:

FAM

Cy5

VIC

ROX

Ability to view data simultaneously and in real-time. “One Step” Workflow.

4 channels required:

This kit is suitable for ABI-7500.

Other devices suitable:
QuantStudio (ThermoFisher), Applied Biosystems, Bio-Rad (CFX96 Touch 1000, iQ5 iCycler), Agilent (MX-3000, Aria-Dx), MGITech, LighCycler 480II & Z480 (Roche), M2000RT Abbott, Pentabase Gentier48E, SLAN-96S, HIMEDIA INSTA Q96 LA1012, HIMEDIA INSTA Q48 LA1023, MygoPro, Rotor-Gene (6000, 3000, Q6Plex), LineGene 9600, DT-Lite, DT96, DT-Prime thermocycler series and other quantitative fluorescence PCR platforms with FAM, VIC/HEX and Cy5 channels.

Box 48-100 Tests
Storage -20°±5°, protected from light
Number of freezing and thawing allowed not exceed 7 times
LoD 500 copies/ml
Positive agreement 100%
Negative agreement 100%

Molecular Analysis for CoViD-19 and variants

Product Specifications Download